IM30-AB
Three-Phase Overcurrent and Earth Fault Relay - Dual Setting
50/51, 50N/51N, 51BF, 68 |
- Three Phase-Fault levels
- Three Earth-Fault levels
- Selecteble double setting program
- Time tagged event recording
- User programmable output relay
- Blocking Output and Blocking input
- Breaker Failure protection
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue

|
IM30-AP
Three-Phase Overcurrent and Earth Fault Relay
50/51, 50N/51N, 51BF, 69 |
- Two Phase-Fault levels
- Two Earth-Fault levels
- Selecteble double setting program
- User programmable output relay
- Blocking Output and Blocking input
- Breaker Failure protection
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue
 |
IM30-BY
Three-Phase Three Elements Overcurrent and
Negative Sequence Relay - Dual Setting
46, 50/51, 51BF, 68 |
- Three independent phase element
- Three Phase-Fault levels
- Two Negative Sequence level
- Selecteble double setting program
- Time tagged event recording
- Blocking Output and Blocking input
- Breaker Failure protection
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue
 |
IM30-C
Capacitor Overload, Earth Fault and Unbalance Protection
37, 46N, 50/51, 50N/51N, 51B |
- Two Overload levels
- Two Unbalance levels
- Two Earth-Fault levels
- Dynamic Compensation of
Capacitors Inherent unbalance
- Time delayed capacitors reenergizatin
- Blocking Output and Blocking input
- Breaker Failure protection
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue
 |
IM30-D
Three-Phase Overcurrent + Directional Earth Fault
50/51, 50N-51N, 51BF, 59Uo, 67N, 68, I2T |
- Three Phase-Fault leves
- Three Directional or not Directional Earth Fault levels with Zero Sequence voltage polarization
- Zero Sequence Overvoltage level
- Breaker interruption energy åI2t
- Inrush current bias1
- Blocking Output and Blocking input
- Breaker Failure protection
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue
 |
IM30-DR
Three-Phase Overcurrent with Directional
Earth Fault+Autoreclosing
46, 50/51, 50N/51N, 51BF, 67N, 68, 79 |
- Two Phase-Fault levels
- Two Earth-Fault levels
- Zero Sequence Overvoltage level
- One Negative Sequence current level
- Four-Shot programmable Autoreclosing
- Reclosure sequence coordination
- Selectable sequence coordination
- Blocking Output and Blocking input
- Breaker Failure protection
- IRIG-B Time Syncronization
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue
 |
IM30-SA
Three-Phase Overcurrent, Earth Fault and Sensitive Earth Fault
46, 50/51, 50N/51N, 51BF, 64 S.E.F., 68 |
- Two Fase-Fault levels
- Two Earth-Fault levels
- One Negative Sequence current levels
- One Sensitive Earth Fault level
- Blocking Output and Blocking input
- Breaker Failure protection
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue
 |
IM30-SR
Three-Phase Overcurrent Sensitive Earth Fault and Autoreclosing
50/51, 50N/51N, 51BF, 64S.E.F., 68, 79 |
- Two Overload levels
- Two Unbalance levels
- Two Earth-Fault levels
- Dynamic Compensation of Capacitors Inherent unbalance
- Time delayed capacitors reenergizatin
- Blocking Output and Blocking input
- Breaker Failure protection
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue
 |
DM33
Three-Phase Directional & Non-Directional
Overcurrent and Earth Fault
27, 50/51, 50N/51N, 51BF, 59, 59Uo, 67, 67N, 68, I2t |
- Three Overcurrent levels
- Three Earth-Fault levels
- Zero Sequence Overvoltage level
- Two over / under voltage level
- Blocking Output and Blocking input
- Breaker Failure protection
- Breaker interruption energy åI2t
- Time tagged multiple event recording
- Modbus Communication Protocol
- UL/CSA listed
|
Download Catalogue
 |
| |
AUTORECLOSING and SYNCHROCHECK RELAYS |
M-ARM513
Multishot Programmable Single/Three Phase Autoreclose 79 |
- Single and Three-Phase reclosure
- Up to Four-shot programmable
autoreclosing cycle
- Self powered digital input
- Modbus Communication Protocol
- Event recording
- Time tagging
|
Download Catalogue
 |
SCM21
Three Input Synchrocheck Relay 25, 27, 59, 81 |
- Synchrocheck relay
- Voltage, frequency and fase displacement check
- Over / Under Voltage
- Over / Under Frequency
- Dead Line / Dead Bus programmable operation
- C/B closing time control
- Event Recording
- Modbus Communication Protocol
- UL/CSA listed |
Download Catalogue
 |